不同热处理方法对鲤鱼DNA的影响及不同DNA提取方法的比较
DOI:
作者:
作者单位:

作者简介:

雍凌 女 硕士生 研究方向为卫生毒理学 E-mail:yongling1234@139.com

通讯作者:

中图分类号:

Q812;S917

基金项目:

转基因生物检测和监测新技术食品中转基因作物溯源体系研究(2008ZX08012-005)


Effects of heating on DNA of carp and the different methods for DNA extraction
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 研究不同加热方法处理后鲤鱼基因组DNA长度和含量的变化,并对4种DNA提取方法进行比较。方法 用电磁炉和微波炉将鲤鱼背部肌肉加热煮沸1、2、3 h取出,再分别用酚氯仿法、Wizard? 试剂盒法、磁珠法和离心柱法提取处理前后鲤鱼基因组DNA,利用琼脂糖凝胶电泳对处理前后的总DNA长度进行比较,再用实时荧光定量PCR法检测所得DNA样品中内参基因β-actin含量的变化。结果 琼脂糖凝胶电泳结果显示,处理后DNA片段明显降解。生鱼肉提取β-actin的量为1 070 213.39拷贝/μl,电磁炉处理1、2、3 h的浓度分别为143 309.6、441 350.43和256 994.16拷贝/μl,微波炉处理1、2、3 h的浓度分别为269 121.17、267 371.16和134 649.97拷贝/μl。酚氯仿法、Wizard? 试剂盒法、离心柱法和磁珠法提取的平均DNA浓度分别为718 944.93、737 945.64、26 751.22和2 934.06拷贝/μl。结论 加热煮沸导致DNA降解,因此加工食品中DNA的检测应当选择较短的目标片段。4种DNA提取方法比较,Wizard? 试剂盒法和酚氯仿法提取的DNA浓度显著高于离心柱法和磁珠法,且离心柱法又高于磁珠法。

    Abstract:

    Objective To investigate the effects of different heating methods on the degradation of carp DNA and to compare different DNA extraction methods. Methods The dorsal muscle of carp was boiled for 1, 2 and 3 h by electromagnetic oven or microwave oven. Genomic DNA of carp meat was extracted by four different methods (phenol/chloroform extraction, Wizard? commercial Kit, Mag-Bind DNA Kit and spin column). The length of DNAs before and after heat treatment was compared by agarose gel electrophoresis. The contents of ?-actin in tested DNA samples were determined by Real-time PCR assays. Results The contents of β-actin DNA after heating for 1, 2 and 3 h in electromagnetic oven were 143 309, 441 350 and 256 994 copy/μl and those in microwave oven were 269 121, 267 371 and 134 650 copy/μl respectively. The contents of raw carp β-actin DNA was 1 070 213 copy/μl, which were decreased significantly after being heated. However, the contents of β-actin DNA would be no significant change with extended heating time. The contents of DNA extracted by phenol/chloroform or Wizard? commercial Kit (718 945 and 737 946 copy/μl respectively) were higher than that by spin column and Mag-Bind DNA Kit (26 751 and 2 934 copy/μl respectively). Conclusions DNA could be degraded by heating for more than 1 h. Therefore, the target fragments of DNA in food selected for DNA detection should be shorter. As for the extraction methods, the contents of DNA extracted by phenol/chloroform ion and Wizard? commercial Kit were higher than that by spin column and Mag-Bind DNA Kit.

    参考文献
    相似文献
    引证文献
引用本文

雍凌,张文众,刘玉梅,贾旭东,严卫星.不同热处理方法对鲤鱼DNA的影响及不同DNA提取方法的比较[J].中国食品卫生杂志,2011,23(3):245-248.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2010-10-28
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
《中国食品卫生杂志》邮寄地址与联系方式变更通知
关闭