    结合不同标准和规范要求,对PetrifilmTM沙门菌测试片(以下简称3M测试片)进行评价。方法 用53个血清型的64株沙门菌及30株不同种属的非沙门菌,对3M测试片的包容性和排他性进行评价;针对12类食品样品,通过与我国国标方法的平行检测,对不同沙门菌检测系统的检验效果进行对比分析。结果 64株沙门菌在所测试4种分离培养基上生长率差异有统计学意义(P<0.05),4种沙门菌分离培养基对30株非沙门菌抑制效果也存在一定差异。不同沙门菌选择性增菌肉汤-选择性培养基组合可影响食品样品中10-1 cfu/25 g染菌水平沙门菌的检出,差异有统计学意义(P<0.05),其中以RV(R10)-3M测试片组合检出率最高,而两种选择性增菌肉汤-选择性培养基组合(如国标法)可提高不同种类食品样品中人工污染低浓度沙门菌的检出。结论 3M测试片以其快速、方便、易保存,且准确性与国标方法相当的特点值得在食品微生物检测行业推广。

    Abstract:

    To evaluate the PetrifilmTM Salmonella express system of 3MTM company following the standards and specifications.Methods The inclusiveness and exclusivity of the PetrifilmTM Salmonella express plate were evaluated using 64 Salmonella strains of 53 serotypes and 30 non-Salmonella strains. Different Salmonella detection systems were compared and evaluated by parallel tests of a wide range of food samples inoculated with Salmonella with the GB method. Results The growth rates of 64 Salmonella strains on four selective media were significantly different (P<0.05), and the growth rate of 30 non-Salmonella also showed difference. Using different Salmonella selective enrichment broth-selective agar combination, the detection rate showed significant difference at 10-1 cfu/25 g level (P<0.05),and the highest detection rate was found by using RV(R10)-3M express plate. The using of two different selective enrichment broths and two selective agars (such as the GB method) could significantly improve the detection rate at 10-1cfu/25 g level in food samples (P<0.05).Conclusion The PetrifilmTM Salmonella express system of 3MTM company was a rapid,convenient Salmonella detection kit and should be promoted in food microbiogy testing labs since it showed the same level of accuracy with the GB method in a wide range of food samples.

    参考文献
    相似文献
    引证文献
引用本文

唐颂,高飞,任秀,张庆生,丁宏,陆苏飚,崔生辉.3M PetrifilmTM检测系统对食品中沙门菌检测的评价研究[J].中国食品卫生杂志,2016,28(2):199-203.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2016-01-20
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2016-04-20
  • 出版日期:
《中国食品卫生杂志》邮寄地址与联系方式变更通知
关闭