基于便携式高灵敏X射线荧光光谱技术快速检测小麦粉中砷、镉、铅含量的研究
作者:
作者单位:

1.上海大学生命科学学院,上海 200444;2.上海海关动植物与食品检验检疫技术中心,上海 200135

作者简介:

钟海林 男 在读研究生 研究方向为食品工程 E-mail: 2505990462@qq.com

通讯作者:

赵超敏 女 高级工程师 研究方向为食品掺假溯源 E-mail: chaomin829@163.com

中图分类号:

R155

基金项目:

上海市委科研项目(20392001700);上海海关科研项目(SHK006-2020);上海市科委项目(20DZ2291900)


Rapid detection of arsenic, cadmium and lead content in wheat flour by portable high-sensitivity X-ray fluorescence spectroscopy technology
Author:
Affiliation:

1.School of Life Sciences, Shanghai University, Shanghai 200444, China;2.Technical Center for Animal Plant and Food Inspection and Quarantine, Shanghai Customs, Shanghai 200135, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 建立便携式高灵敏X射线荧光光谱法直接快速测定小麦粉中砷、镉、铅含量的分析方法。方法 取部分样品至进样杯中,然后直接将进样杯放入便携式高灵敏X射线荧光光谱仪进行检测,并对仪器检测时间、样品紧实度、检测厚度等条件进行优化,将最优条件应用于小麦粉的检测。结果 各元素的精密度的相对标准偏差(RSD,n=6)在0.6%~4.8%之间,基质中加标回收率为78.3%~120.4%,铅、镉、砷的检出限分别为0.06、0.06、0.05 mg/kg、定量限分别为0.19、0.19、0.17 mg/kg。对便携式高灵敏X射线荧光光谱法和电感耦合等离子体质谱法检测结果进行比较,相关系数大于0.98。结论 该方法精密度比较高,检出限与定量限良好,基本上能够满足小麦粉中多种重金属元素同时快速检测的要求。

    Abstract:

    Objective A portable high-sensitivity X-ray fluorescence spectrometry method was established to directly and quickly determine the content of arsenic, cadmium and lead in wheat flour.Methods Part of the sample was put into the sample cup, and then directly put the sample cup into the portable high-sensitivity X-ray fluorescence spectrometer for testing. The testing time, sample compactness, and testing thickness of the instrument were optimized and applied to the detection of different types of wheat flour.Results The relative standard deviation (RSD, n=6) of the precision was between 0.6% and 4.8%, and the recovery rate was 78.3%-120.4%. The detection limits of lead, cadmium and arsenic were 0.06 mg/kg, 0.06 mg/kg, 0.05 mg/kg, the quantification limits were 0.19 mg/kg, 0.19 mg/kg and 0.17 mg/kg, respectively. The correlation coefficient of portable highly sensitive X-ray fluorescence spectrometry and inductively coupled plasma mass spectrometry was greater than 0.98.Conclusion The method has relatively high precision, good detection limit and quantification limit, and can meet the requirements of simultaneous rapid detection of multiple heavy metal elements in wheat flour.

    参考文献
    相似文献
    引证文献
引用本文

钟海林,张润何,赵超敏,钮冰,樊祥,蔡文萱,吴池莹,许晓薇,邓晓军.基于便携式高灵敏X射线荧光光谱技术快速检测小麦粉中砷、镉、铅含量的研究[J].中国食品卫生杂志,2022,34(4):744-749.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2022-01-05
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-08-26
  • 出版日期:
《中国食品卫生杂志》邮寄地址与联系方式变更通知