基质辅助激光解吸电离飞行时间质谱技术对阪崎克罗诺杆菌的鉴定及溯源
作者:
作者单位:

(1.大连工业大学生物工程学院,辽宁 大连 116034;2.中国检验检疫科学研究院, 北京 100176;3.国家乳制品质量监督检验中心,黑龙江 哈尔滨 150086)

作者简介:

王伟 女 硕士生 研究方向为微生物溯源方法 E-mail:3169324291@qq.com通信作者:┣┣(中)通信作者┫┫卢行安 男 研究员 研究方向为微生物检验质量控制和溯源方法 E-mail:luxa@sina.com

通讯作者:

中图分类号:

基金项目:

科技部“食品安全关键技术研发”重点专项(2017YFC1601401)


The identification of Cronobacter sakazakii and its traceability by matrix-assisted laser desorption ionization-time of flight mass spectrometry
Author:
Affiliation:

(1.School of Biological Engineering, Dalian Polytechnic University, Liaoning Dalian 116034, China;2.Chinese Academy of Inspection and Quarantine, Beijing 100176,China;3.National Dairy Engineering and Technical Research Center, Heilongjiang Harbin 150086, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 研究不同样品前处理方法对VITEK基质辅助激光解吸电离飞行时间质谱(VITEK MALDI-TOF MS,以下简称VITEK MS)鉴定阪崎克罗诺杆菌的影响及该方法对阪崎克罗诺杆菌的分型溯源能力,研究VITEK MS与MALDI 7090TM MALDI-TOF/TOF MS(以下简称MALDI 7090)所得图谱的异同。方法 选取3种不同样品前处理方法处理18株阪崎克罗诺杆菌野生菌株、2株阪崎克罗诺杆菌标准菌株和2株非阪崎克罗诺杆菌标准菌株,比较VITEK MS鉴定结果与传统鉴定结果的一致性;通过VITEK MS的鉴定结果和图谱的比对,研究不同样品前处理方法对阪崎克罗诺杆菌鉴定的影响;利用VITEK MS质谱图特征峰的聚类分析,对20株阪崎克罗诺杆菌进行溯源研究;同时比较VITEK MS与MALDI 7090所得图谱,研究两者的异同。结果 20株试验菌株的VITEK MS鉴定结果均为阪崎克罗诺杆菌,与传统的鉴定结果一致,并与2株非阪崎克罗诺杆菌标准菌株能明显地区分;3种不同样品前处理方法得到的鉴定谱图与标准谱图比对获得的鉴定结果可信度之间差异无统计学意义(P>0.05),但质谱图中质谱峰数量和相对峰强度有明显差异,其中甲酸提取法在2 000~15 000 m/z范围内,相对峰强度>5 mV的质谱峰数量达15个以上。在相似水平为80%的条件下,VITEK MS的聚类分析将甲酸提取法的20株阪崎克罗诺杆菌分为5个群,通过聚类分析及菌株来源能够推测阪崎克罗诺杆菌传播途径。VITEK MS和MALDI 7090得到的谱图,两者特征峰的出峰位置与相对峰强度无明显差异。结论 MALDI-TOF MS技术可以准确鉴定阪崎克罗诺杆菌;甲酸提取法更适用于阪崎克罗诺杆菌的MALDI-TOF MS鉴定;MALDI-TOF MS技术对阪崎克罗诺杆菌的溯源研究具有重要价值;VITEK MS与MALDI 7090所得谱图无明显差异。

    Abstract:

    Objective VITEK matrix-assisted laster desorption ionization-time of flight mass spectrometry (VITEK MALDI-TOF MS,hereinafter referred to as VITEK MS). To study the impact of different sample preparation procedures for Cronobacter sakazakii identification and its traceability. And two data acquisition softwares of VITEK MS and MALDI 7090 were used to compare the differences of mass spectrograms between them. Methods Twenty two strains, including 18 isolated Cronobacter sakazakii strains, two Cronobacter sakazakii reference strains, one Enterobacter cloacae reference strain and one Citrobacter freundii reference strain were prepared respectively by three different preparation procedures, including direct transfer method, formic acid extraction method and formic acid-acetonitrile extraction method, and analyzed by MS. A detailed analysis of mass spectrograms was obtained from the software of VITEK MS. The result were compared with biochemical result. Then, the impact of sample preparation method on the identification result was evaluated by researching the consistency of result derived from three different preparation method, The traceability of 20 Cronobacter sakazakii strains was also investigated by the cluster analysis of VITEK MS result. The same strains were analyzed by MALDI 7090, and the mass spectrograms were compared with those by VITEK MS. Results The 20 strains were identified by VITEK MS as Cronobacter sakazakii, which were in consistent with biochemical result and could be distinguished from Enterobacter cloacae and Citrobacter freundii. There was no significant difference in the result confidence among the three different preparation procedures(P>0.05), but the number of mass peaks and their relative intensities showed remarkable difference. The formic acid extraction method achieved spectra consisting of >15 peaks and mass ranges of 2 000-15 000 m/z, of which relative intensities were >5 mV. At similarity level of 80%, the 20 strains prepared by the formic acid extraction method were classified into 5 clusters by the cluster analysis of VITEK MS result, through which the transmission route of Cronobacter sakazakii could be identified. There was no obvious difference in the peak positions and relative intensity between VITEK MS and MALDI 7090. Conclusion MALDI-TOF MS was considered as a reliable technique in the identification of Cronobacter sakazakii. The formic acid extraction method was more suitable for the identification of Cronobacter sakazakii by MALDI-TOF MS, which will be a useful technique for Cronobacter sakazakii trace. There was no obvious difference in the mass spectrograms between VITEK MS and MALDI 7090.