1.School of Public Health,Shandong Second Medical University, Shandong Weifang 261000, China;2.Shandong Institute for Food and Drug Control, Shandong Ji’nan 250101, China;3.Shandong Research Center of Engineering and Technology for Quality Control of Food for Special Medical, Shandong Ji’nan 250101, China;4.China National Center for Food Safety Risk Assessment, Beijing 100022, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 利用液液萃取-固相萃取法去除可可制品中脂肪含量和干扰杂质,建立高效液相色谱法检测其中二氢槲皮素的含量。方法 样品经甲醇-2%乙酸水(V∶V=1∶1)提取后,先采用液液萃取净化方式去除溶液中脂肪含量,后以亲水亲脂固相萃取柱进行二次净化,以0.1%乙酸水-甲醇为流动相,C18反相色谱柱分离,使用带二极管阵列检测器的高效液相色谱仪进行分析。结果 二氢槲皮素在0.1 μg/mL~100 μg/mL范围内呈现良好的线性关系,线性相关系数为0.999 9,检出限为1 mg/kg,定量限为3 mg/kg,平均回收率为101.7%~106.7%,RSD为0.35%~1.60%(n=6)。结论 该方法能够去除可可制品中的脂溶性杂质,灵敏度高、准确度好,适用于高脂食品中二氢槲皮素含量的准确测定。

    Abstract:

    Objective In the experiment,using liquid-liquid extraction solid-phase extraction method to remove fat content and interfering impurities from cocoa products,establishing a high performance liquid chromatography method for detecting the content of dihydroquercetin.Methods After the sample was extracted with methanol-2% acetic acid water (V∶V=1∶1),the fat content in the solution was first removed by liquid-liquid extraction purification,then it was secondary purified by hydrophilic and lipophilic solid-phase extraction column.The mobile phase was 0.1% acetic acid water-methanol,and it was separated by C18 reversed-phase chromatographic column.Finally,it was analyzed by high performance liquid chromatography with diode array detector.Results The dihydroquercetin showed a good linear relationship in the range of 0.1-100 μg/mL,the linear correlation coefficient was 0.999 9,the detection limit was 1 mg/kg,the quantitative limit was 3 mg/kg,the average recovery rate was 101.7%-106.7%,and the RSD was 0.35%-1.60% (n=6).Conclusion The method can remove fat soluble impurities in cocoa products,with high sensitivity and accuracy,and is suitable for accurate determination of dihydroquercetin content in high-fat foods.